Parameter Assessment of Beam Transport Line for Nuclear Physics Research
Author affiliations
DOI:
https://doi.org/10.15625/0868-3166/29/3SI/14327Abstract
The IBA CP30 cyclotron was installed at the 108 Central Hospital in Hanoi, Vietnam. A proton beam with energy range from 15 to 30 MeV can be delivered by this facility. Currently, facility is mainly used for medical radioactive isotope production. There is an idea to use this accelerator for scientific research as well. For this purpose, a new beam line should be designed. A high energy resolution with minimum momentum spread is a key point for designing. A preliminary design of the beam line using matrix codes, modeling 3D optical elements, magnetic field calculations, and beam dynamics analysis is presented in this paper.Downloads
Downloads
Published
How to Cite
Issue
Section
License
Communications in Physics is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Copyright on any research article published in Communications in Physics is retained by the respective author(s), without restrictions. Authors grant VAST Journals System (VJS) a license to publish the article and identify itself as the original publisher. Upon author(s) by giving permission to Communications in Physics either via Communications in Physics portal or other channel to publish their research work in Communications in Physics agrees to all the terms and conditions of https://creativecommons.org/licenses/by-sa/4.0/ License and terms & condition set by VJS.