Mercury (II) sensors using Co\(_{3}\)O\(_{4}\) fabricated electrochemical method
Author affiliations
DOI:
https://doi.org/10.15625/0868-3166/21857Keywords:
cobalt oxide, mercury, electrochemical sensor, electrochemical depositionAbstract
A simple and rapid electrochemical method has been developed for the synthesis of Co₃O₄ material via electrochemical deposition on an ITO substrate for use as a sensor electrode for mercury (II) detection. The morphology and structure of the Co₃O₄ were characterized using SEM, EDX, and XRD, revealing a nanosheet structure of the material. The synthesis conditions of the material were systematically investigated. The sensor properties of the fabricated electrode, evaluated using differential pulse anodic stripping voltammetry (DP-ASV), demonstrated a linear detection range for Hg(II) ions from 0.1 to 12 µM, with a sensitivity of 14.559 µA cm⁻¹ µM⁻¹ and a detection limit of 0.06 µM.
Downloads
References
H. Teng, A.R. Altaf, Elemental mercury (Hg0) emission, hazards, and control: A brief review,
J. Hazard. Mater. Adv. 5 (2022) 100049.
B. Kaur, R. Srivastava, B. Satpati, Ultratrace detection of toxic heavy metal ions found in water bodies using hydroxyapatite supported nanocrystalline ZSM-5 modified electrodes,
New J. Chem. 39 (2015) 5137-5149.
K. Annadurai, V. Sudha, G. Murugadoss, R. Thangamuthu, Electrochemical sensor based on hydrothermally prepared nickel oxide for the determination of 4-acetaminophen in paracetamol tablets and human blood serum samples,
J. Alloys Compd. 852 (2021) 156911.
A. Yamuna, C.-Y. Hong, S.-M. Chen, et al., Highly selective simultaneous electrochemical detection of trace level of heavy metals in water samples based on the single-crystalline Co3O4 nanocubes modified electrode,
J. Electroanal. Chem. 887 (2021) 115159.
A. Kulpa-Koterwa, T. Ossowski, P. Niedziałkowski, Functionalized Fe3O4 nanoparticles as glassy carbon electrode modifiers for heavy metal ions detection—a mini review,
Mater. 14 (2021) 7725.
J. Xu, Y. Zhang, X. Zhu, G. Ling, P. Zhang, Two-mode sensing strategies based on tunable cobalt metal organic framework active sites to detect Hg2+,
J. Hazard. Mater. 465 (2024) 133424.
Z. Zhang, Z. Liang, M. Huang, et al., Design and Synthesis of Multilevel Structured Co3O4 Double-shell Dodecahedron as Non-enzymatic Electrochemical Sensor for H2O2 Detection,
Electrochemistry (2024) 24-00087.
C.-Y. Yoo, J. Park, D.S. Yun, et al., Crucial role of a nickel substrate in Co3O4 pseudocapacitor directly grown on nickel and its electrochemical properties,
J. Alloys Compd. 676 (2016) 407-413.
S. Luo, D. Yang, J. Feng, K.M. Ng, Synthesis and application of non-agglomerated ITO nanocrystals via pyrolysis of indium–tin stearate without using additional organic solvents,
J. Nanopart. Res. 16 (2014) 1-12.
L. Yu, P. Zhang, H. Dai, et al., An electrochemical sensor based on Co3O4 nanosheets for lead ions determination,
RSC Adv. 7 (2017) 39611-39616.
N.Q. Dung, T.Q. Tran, P.H. Chuyen, et al., Straightforward method for the electrochemical identification of dopamine in the presence of uric acid and ascorbic acid,
Meas. Sci. Technol. (2024).
C. Zhang, S. Wu, Y. Yu, F. Chen, Determination of thiourea based on the reversion of fluorescence quenching of nitrogen doped carbon dots by Hg2+,
Spectrochim. Acta A 227 (2020) 117666.
X. Han, Z. Meng, H. Zhang, J. Zheng, Fullerene-based anodic stripping voltammetry for simultaneous determination of Hg(II), Cu(II), Pb(II) and Cd(II) in foodstuff,
Microchim. Acta 185 (2018) 1-9.
S.A. Kitte, S. Li, A. Nsabimana, et al., Stainless steel electrode for simultaneous stripping analysis of Cd(II), Pb(II), Cu(II) and Hg(II),
Talanta 191 (2019) 485-490.
H. Xing, J. Xu, X. Zhu, et al., Highly sensitive simultaneous determination of cadmium (II), lead (II), copper (II), and mercury (II) ions on N-doped graphene modified electrode,
J. Electroanal. Chem. 760 (2016) 52-58.
Downloads
Published
How to Cite
Issue
Section
License
Communications in Physics is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Copyright on any research article published in Communications in Physics is retained by the respective author(s), without restrictions. Authors grant VAST Journals System (VJS) a license to publish the article and identify itself as the original publisher. Upon author(s) by giving permission to Communications in Physics either via Communications in Physics portal or other channel to publish their research work in Communications in Physics agrees to all the terms and conditions of https://creativecommons.org/licenses/by-sa/4.0/ License and terms & condition set by VJS.