Cold Atmospheric Pressure Gliding arc Plasma Jet for Decontamination
Author affiliations
DOI:
https://doi.org/10.15625/0868-3166/24/3S2/5055Keywords:
CAP, antimicrobial effect, gliding arc, wound healingAbstract
A cold atmospheric pressure gliding arc plasma jet hasbeen developed and applied to disinfection. The size of the plasma output is
about 6 mm in diameter and 10 mm in length. Ar gas at a flow rate of 10 slm
and 25 W plasma power are used. Plasma discharge is produced between the
divergent electrodes and the jet appears as an effluence of the gas flow.
When a \textnormal{pseudomonas} culture is placed at 8 mm below the
torch for 1minute, where the gas is at room temperature, the
bacteria within a 16 mm diameter circle are almost completely killed. As the
UV radiation is well below the safety regulation, the bacteria are
inactivated by the total effect of UV radiation and others like the reactive
species and the charged particles.
Downloads
Downloads
Published
How to Cite
Issue
Section
License
Communications in Physics is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Copyright on any research article published in Communications in Physics is retained by the respective author(s), without restrictions. Authors grant VAST Journals System (VJS) a license to publish the article and identify itself as the original publisher. Upon author(s) by giving permission to Communications in Physics either via Communications in Physics portal or other channel to publish their research work in Communications in Physics agrees to all the terms and conditions of https://creativecommons.org/licenses/by-sa/4.0/ License and terms & condition set by VJS.